The following table lists the cli utility parameters:
Parameter |
Description |
---|---|
<user_name> |
Defines the Control-M/EM database user name. |
<password> |
Defines the Control-M/EM database user password. |
<password file> |
Flat file containing an unencrypted user name and password on separate lines in the format: user=<emUser> |
<Server Name> |
Defines the host name of the workstation running Control-M/EM database Server. NOTE: If you need to address a GUI server and multiple GUI servers exist, set this parameter to the logical name of the relevant GUI server. |
<timeout in seconds> |
Defines the time, in seconds, that the utility waits for a response. Timeout is used to override the default waiting period (120 seconds). NOTE: Do not use timeout with commands that do not return a response (-JOB_DELETE and ‑MEM_DELETE). |
-DDMM |
If specified, reverses the Odate format, as described below. |
-BY_FORCE |
Forces the specified folder or calendar. Use this option during upload only. |
-ACTION_REASON |
A note saved in the audit report explaining the purpose for performing the action. |
-ACTION_NOTE |
A note saved in the audit report justifying the performance of the action. |
<cmd> |
The syntax for additional commands that are available for specifying with the cli utility. For more information, see cli cmd parameters. |
<ctm_name> |
Defines the Control-M name. |
<job_name> |
Defines the name of the job. |
<folder_name> |
Defines the name of the folder. |
<sub_folder_name> |
Defines the name of sub folder. |
<Control-M Calendar> |
Defines the name of the Control-M Calendar you want to upload or download. |
<Odate> |
Specify either as: MMDD or YYYYMMDD. <Odate> may also be ODAT for Control-M version 6.0.00 or later (Order or Force Folder in the Original Scheduling Date) If the -DDMM is specified, <Odate> can be specified as DDMM or DDMMYYYY |
<folder> |
Valid values are:
|
<Duplication> |
Specify if <folder> is RECENT or <TableID>, otherwise do not specify. Specify one of the following values:
|
<Wait_Odate> |
Determines whether you should wait for the Order date to run the job.
Y - Wait for Order date to run job. N - Run the job immediately. For Control-M for Distributed Systems this field is optional. If omitted, the job runs immediately. If not omitted, the only valid value is Wait_Odate, which means wait for Order date to run the job. |
<With_Hold> |
Enables you to hold all jobs immediately after they are ordered. Specify one of the following values:
|
<UNIQUE_FLOW> |
Determines if a flow in a folder is ordered uniquely. This is only relevant if you are ordering a single folder created in Control-M/EM version 8.0.00 and above. A unique suffix is added to every condition name. Valid values:
|
<library> |
(Control-M for z/OS only) Defines the name of the library in which the folder is located. |
<RBC> |
Indicates whether the calendar is a Rule Based Calendar (RBC). Values:
|
Parent Topic |