The following table describes Control-M/EM general system parameters in the Advanced section of the CCM.
Parameter |
Description |
---|---|
act_chk_inpermitt_gcs_gui |
Do not modify this parameter unless requested by BMC Software Customer Support. Default: N |
ActivateApplications4NonAdmin |
Determines whether to activate applications for users who do not have administrator rights. Valid Values:
Default: 1 |
AlertsLimit |
Limits the number of alerts NOTE: If the value is set to 0, the Control-M client shows unlimited number of alerts. |
AllowListEMUserNames |
Determines whether users can view a list of user names (used by Control-M for AFT configuration plug-in). Valid values:
|
AllowLoginWithNonTrustedSSLCertificate |
Determines whether to enable users to log in to the Control-M client and and CLI utilities when the SSL certificate is not trusted. NOTE: This parameter does not affect the CCM. If the SSL certificate is not trusted, a warning message appears but the login process continues. Valid values:
Default: 1 |
AnnotationDefaultCategory |
Sets the default value when an annotation description is missing. Default: Utility |
AnnotationDefaultNote |
Sets the default value when an annotation note is missing Default: Command line utility invocation |
ApplicationFieldIsMandatory |
Determines whether the Application field is mandatory for job definition. Valid values:
Default: 0 |
ApplyAnnotationForAuditContext |
Specifies the activities that require user annotations. Valid values:
Default: AUTH SCHED J_CONT J_INFO RES ALERT ACCOUNT OPER CONFIG CTMSEC DB_MAINT |
AuditCleanupIntervalMinutes |
When cleanup of audit information from the Control-M/EM database is automatic, this parameter specifies the interval, in minutes, at which the GUI Server performs its cleanup operations. Valid values: 60 and up Default: 360 (minutes) |
AuditCleanupOn |
Specifies whether cleanup of audit information from the Control-M/EM database should occur automatically. Note: When automatic cleanup of audit information is activated, the GUI Server first waits the specified number of minutes (as specified in the AuditCleanupIntervalMinutes system parameter) before cleaning the auditing table the first time. Valid values:
Default: 1 |
AuditFullDefinitionChanges |
Determines whether to audit all changes to the job definition when it is updated. Valid values: 0,1 Default: 1 - Audit all changes when job definition is updated |
AuditHistoryDays |
When cleanup of audit information from the Control-M/EM database is automatic, this parameter specifies the number of days that audit information is retained before being cleaned from the Control-M/EM database. Minimum values: 1 Default: 7 |
AuthenticationMethod |
Name of the external authentication plug-in. Default: null (for internal Control-M/EM authentication) |
AutomaticOrderMethodByDefault |
Determines whether the default for folders that are created by Order Method is automatic or manual. Valid values:
Default: 1 |
bulk_def_size |
Default bulk size for database bulk operation. Valid values: 10-10000 Default: 100 |
bulk_def_storage_len |
Default value for storage length in bulk operation. Must be at least as long as the longest field involved in the bulk operation. Default: 264 |
CentralDeployLocation |
Defines a network location where the installation packages for Agent Deployment are saved. You must define this parameter if you want to upgrade Control-M/Agents from a network location, as described in Upgrading Control-M/Agents. NOTE: After you defined the value for this parameter, restart the Control-M/EM Configuration Agent. Default: Empty |
ChallengeResponseTimeout |
Time interval in seconds after the server issues a request and receives a response from the client. If a response is not received during this interval, the server sends a FAILURE message and terminates the communication. Default: 60 |
CheckDifferentHosts |
Identifies if the component with the same name should be checked on other machines when registering in the Database. Valid Values:
Default: 1 |
CheckLimitsSwitch |
Determines whether to check if OS resource limits are set appropriately. Valid values:
Default: 1 |
CGSCommUserIGd |
Defines the ID that GCS uses to identify itself to Convrol-M. This user must be defined in the Control-M with add or delete condition privileges. Valid values: <String expression>. Default: GCSERV |
ClientSSO |
Determines whether the Disable SSO mode checkbox appears in the Control-M login window. Default: Off Valid values:
|
CollectEMStatistics |
Determines whether the Control-M/EM Statistics collection mechanism is on or off. Valid values:
Default: 1 |
CollectStatisticsByField |
Specifies the job field by which statistics are collected for distributed jobs. Valid values: Control-M job definition fields Default: Jobname
|
CollectzOSUserDaily |
Specifies whether the Gateway automatically requests updates from Control-M for z/OS for the following information:
The information is saved in the Control-M/EM database. Valid values:
Default: 1 |
ConsiderDSN |
Specifies whether the ordering job and table keys (used when sending job ordering information from Control-M for z/OS to the Gateway) includes dataset names. Typically, the dataset name is changed for each job order. Valid values:
Default: 1 |
ControlM_EM_Version |
Specifies the Control-M/Enterprise Manager version. |
ControlResourceForSMARTTable |
Enables definition of Control Resources for SMART and Sub folders in Control-M Servers from release 7.0.00.200, however Control-M/EM clients of versions lower than 7.0.00.300 , can not login to the Control-M/Enterprise Manager. Valid values:
Default: 0 |
CTMSyncExceptions |
Excludes folders from automatic synchronization (upload/download/delete) by the Gateway where the synchronization mode is set to No Synchronization. EXAMPLE: If the Control-M synchronization mode is set to Update Control-M/Server and Control-M/EM and this parameter is defined as "A*,B*" folders that start with A or B are not downloaded automatically from Control-M/Server to Control-M/EM and are not uploaded automatically from Control-M/EM to Control-M/Server. You can set this parameter for each Control-M/Server separately or for all (*). Valid values: A valid regular expression (see Pattern matching strings). Default: Empty (no exceptions). If you modify the value, you must recycle the GUI Server and the Gateway components. |
DatabaseCheckInterval |
Amount of time between database availability checks by certain server components. Valid values: Do not change this parameter unless instructed to do so by BMC Software Customer Support. Default: 10 |
DatabasePoolSize |
Determines the maximum number of connections to the database retained in the connection pool of each server component. Valid values: Do not change this parameter unless instructed to do so by BMC Software Customer Support. Default: 5 |
DatabaseRetries |
The maximum number of attempts by a server component to perform certain actions with the database. Valid values: Do not change this parameter unless instructed to do so by BMC Software Customer Support. Default: 10 |
DatabaseRetryInterval |
The amount of time between the attempts set in DatabaseRetries. Valid values: Do not change this parameter unless instructed to do so by BMC Software Customer Support. Default: 10 |
DataSegmentLimitGB |
Specifies the data segment size limit in GB. Default: 2 |
DefaultAverageTime |
Average run time for jobs with no statistics. This value is often used if no statistics are available. Valid values: Any valid time, entered in the following format: MM:SS Default: 00:05 |
DefaultCTMExcludeRBC |
Determines Excluded Rule-based Calendar (RBC) support in a newly defined Control-M/Server. The value is overridden by the value set in the Control-M/Server system parameter EXCLUDE_RBC_ENABLED. Valid values:
Default: Y If this feature was disabled during the fix pack installation, you need to change RBC names that start with ! and run the enable_exclude_rbc.pl perl script from the <scripts> directory. |
DeleteChunkSize |
Maximum number of rows to be deleted by a single SQL statement, used by purge_runinfo and erase_audit_data scripts. Default: 10,000 Valid values: A whole number equal to or greater than 1. |
DirectoryConnRefreshTime |
Specifies the time interval, in seconds, passed from last refresh, after which EM refreshes LDAP connection during authentication. Valid values: 1-60 seconds Default: 45 |
DirectoryDefaultDomain |
Specifies the default LDAP directory domain name for user authentication |
DirectoryServiceAuth |
Determines the Directory Service mode for authentication purposes. Valid values:
Default: Off |
DirectoryServerChaseRef |
Determines if LDAP search action should chase referrals suggested by the server. Valid values:
Default: 0 |
DirectoryServerConnAttempts |
Specifies the maximum unsuccessful connection attempts allowed to the LDAP server. Default: 3 |
DirectoryServerConnNetworkTimeout |
Specifies the connection network timeout to LDAP server in seconds. Valid values: 5-120 Default: 20 |
DirectoryServerHostPort |
The full domain name of the host on which the LDAP server is installed and the port on which to communicate with the LDAP server. Format: full domain name:port number Example: CTMhost1.DOMAIN1.level1:389 Default: <null> Note: Multiple LDAP servers can be defined. This enables Control-M/EM to perform authentication against backup LDAP servers when the primary server is unavailable. |
DirectoryServiceSpecialChar |
Sets the list of characters considered to be special in LDAP. Default: \() |
DirectoryServiceTimeout |
Sets the time interval in seconds for which EM waits for LDAP actions return. Valid values: 1-60 seconds Default:10 |
DirectoryServiceUseEscChar |
Determines if the escape character should be overridden in Directory Service when sending the search string. Valid values:
Default: 1 |
DirectorySearchUserDN |
Stores the LDAP Domain Name (DN) credentials for a special user who has read access to the directory. This parameter is mandatory if the value of the DirectoryServiceType parameter is Active Directory, otherwise it is optional. If no value is used, the parameter value is interpreted as an anonymous user (Default). Valid values:Either the URL notated definition of the user ID or its DN. EXAMPLE:
|
DirectorySearchUserPwd |
Stores the LDAP password for the search user defined in the DirectorySearchUserDN parameter who has read access to the directory. Optional if the value of the DirectorySearchUserID parameter is empty or anonymous. Valid Values: The value is an encrypted password string. which is entered into the parameter value field as regular text and is then converted to an encrypted string before being stored in the database. Thereafter, the displayed value is the encrypted string whenever the parameter is accessed in the System Parameters window. If no value is used, the parameter value is interpreted as blank (Default). |
DirectoryServiceType |
Defines the LDAP directory type or vendor that is available to the enterprise, for example, Active Directory, iPlanet, Apache Directory. This definition points to the relevant parameter load section in the DirectoryServiceType.cfg configuration file in the ctm_em/etc. The value of this parameter should be listed in this file. By default, two default directory service types (Active Directory and iPlanet) are provided in the configuration file. The default value of this parameter is Active Directory. |
DirectoryServiceValidation |
Determines the validation level of Directory Service parameters when connecting to LDAP. Valid values:
Default: 1 Refresh type: manual The best configuration duration time can be achieved by setting this parameter to bypass validation actions during Control-M/EM startup or LDAP activation. This can be done after validating your configuration at least once to ascertain that all the configuration values are valid. |
DirectoryServerProtocol |
Determines the security level of communication with the Directory Server. Valid values:
Default: TCP |
DirectoryUsersSearchRoot |
Defines the starting point (domain, country, and so on) in the directory tree structure. The domain name values in this field supports both dot separated or DN format, For example, "PRODUCTION.bmc.com" or "c=us, o=acme, dc=root". You can define multiple starting leafs by separating them with colons (":"). The lookup order is from left to right, according to the domain list order. If the value of this parameter is NULL then a default value will be used, only if the DirectorySearchUserDN parameter is not blank. The DirectoryUsersSearchRoot parameter can only be left blank if the DirectorySearchUserDN has a configured value. The default value of DirectoryUsersSearchRoot is the domain of the search user. For example, if the DirectorySearchUserDN parameter value is "jsmith@PRODUCTION.bmc.com", then the default value of DirectoryUsersSearchRoot parameter would be "PRODUCTION.bmc.com". |
EmailSender |
Defines the email address that issues the high availability alert. |
EmailServer |
Defines the E-mail server that is used to send notifications emails to Control-M Workload Change Manager end users. |
EmailRecipients |
Defines the email addresses that receive the high availability alerts. The email addresses must be separated by a comma. |
EmdefValidationVersion |
Sets the validation version used by the emdef utilities. Valid Values:
|
EnableLoadBalancerRouter |
Enables you to define a third party Network Load Balancer Router, which sends the jobs to specific Control-M/Agents according to its own load balancing definitions. Valid Values:
Default: False |
EnableRemoteBrowsing |
Enables you to browse for a script in a file system on a Control-M/Agent node from the job properties pane. Valid values:
Default: Y |
Environment Title |
Defines the logical name for the Control-M/EM environment, which appears in the Control-M title bar. Valid values: Any. Free Text field |
GCSCommUserId |
Defines the ID that GCS uses to identify itself to Control-M. This user must be defined in the Control-M/Server with Add or Delete permissions. Default: GCSERV |
GlobalCondsTimestampActivation |
Sends a Timestamp with every Global condition action (Add or Delete condition). Valid Values:
Default: 0 NOTE: You should only enable the feature if is supported by Control-M/Server. |
HandleAlertsOnRerun |
Determines how to handle alerts when a job is rerun. Valid values:
Default: 0 |
HostPort |
Defines the hostname and port number or a port range for all components. NOTE: If you want to define a different host and port/port range for each component instance, you need create additional HostPort system parameters, as described in Defining Control-M/EM system parameters. Format:
|
I18N |
Indicates whether the system is configured for CJK languages or Latin1 languages. Warning: This parameter is automatically set during installation, according to the specified choices, and must not be changed manually. For more information, see Control-M Installation Valid values:
Default: latin1 or cjk |
IPV_MODE |
Determines whether to enable IPV6. Valid Values:
Default: IPV4 How / where to set: In the config.dat file of Control-M/Server and the CONFIG.dat file of Control-M/Agent, set the IPV_MODE parameter to DUAL and then restart both Control-M/Server and Control-M/Agent. NOTE: If Control-M/Server and/or Control-M/Agent are installed on AIX, verify that the fix for APAR IV23320 is installed. If you want to enable IPV6 before installation, see Setting environment variables in UNIX. |
KeepAliveTimeout |
Determines the number of seconds before the user is logged out while there is no network activity between Control-M Web and the server. Default: 600 seconds |
Language |
Language for the Control-M/EM application. These values are not case-sensitive. Valid values:
Default: use_account_locale |
LimitGCDistribActivate |
Enables and disables limitations on the distribution of global conditions using the Global Conditions Distribution facility. Valid values:
conditions according to limitations defined using the LimitGCSDistribMaxDays and LimitGCSDistribExcludeDates parameters.
limitations on the distribution of global conditions. Default: _1 |
LimitGCDistribExcludeDates |
Dates for which global conditions are distributed, regardless of limitations specified using the LimitGCSDistribMaxDays parameter. Dates are specified in mmdd format and separated with commas. Default: STAT |
LimitGCDistribMaxDays |
The range of days within which conditions can be distributed. Valid values: 1-28 Default: 7 |
LMGUI_Communication_Cfg |
License Manager address. Not yet implemented. Default: null |
LockAccountForMinutes |
Time interval, in minutes, after which an account that was automatically locked is automatically unlocked. (Accounts locked by an administrator are not unlocked automatically.) If set to 0, the account is not automatically unlocked but an administrator can manually unlock it. Valid values:Positive integer values Default: 0 |
MainEMServiceContext |
Determines the logical name context of GUI Server that the Control-M Self Service Web server must connect to. Valid values: GUI Server logical name Default: Empty |
MaxAuditsToDelete |
When cleanup of audit information from the Control-M/EM database is automatic, this parameter specifies the maximum number of audit records to delete during each automatic cleanup operation. If the number of audit records to clean is higher than this number, no records are deleted and a message is issued to the GUI Server diagnostic log asking you to clean audit records manually using the erase_audit_data script. Valid values:Positive integer values Default: 2000 |
MaxDaysAlertRetained |
Defines the number of days the alert is retained in the database. Default: 30 |
MaxRecentItemsInList |
Defines the number of recent items in any list. Default: 40 |
MaxPasswordLength |
The maximum number of characters for user passwords. Note: If a Control-M administrator uses the Control-M/EM Authorization to set a password, this parameter is ignored. Valid values: Any value between the MinPasswordLength and 32 (inclusive). Default: 32 |
MaxTableJobsToAudit |
The maximum number of jobs in the table to be audited. Valid values: Any whole number that is equal to or greater than 1. Default: 1000 |
MeasurementDaysToKeep |
Defines the number of days to keep collected metrics data. Default: 90 days |
MFTActiveConnectionsChartUnits |
Determines the units that appear in the Bit Rate tab in the Active Connections area. Valid values:
Default: KB |
MFTRefreshRate |
Determines the number of seconds between each refresh in the MFT dashboard. Default: 60 |
MFTTrafficLoadChartUnits |
Determines the units that appear in the Volume tab in the Traffic Load area. Valid values:
Default: KB |
MinPasswordLength |
The minimum number of characters for user passwords. Note: If a Control-M administrator uses the Control-M/EM Authorization window to set a password, this parameter is ignored. Valid values: Any value between 1 and the MaxPasswordLength (inclusive). Default: 6 |
ModifyJobFieldsBlock |
Determines whether to disable editing of the Command line and Node ID Group fields for all non-admin users in the Monitoring domain. Valid values:
|
NrHandledAlarms |
The maximum number of handled alerts saved in the database (in addition to not-yet-handled alerts). Valid Values:Positive integer values Default: 2000 Note: When set to 0, there is no maximum number of handled alerts, and they will be deleted if they pass the threshold defined in MaxDaysAlertRetained parameter value. |
NumberofConnectionAttempts |
Defines the number of connection attempts between the client (CCM or Control-M) and the GUI Server for connection recovery. Default: 5 |
NumberOfEstimationRunTime |
Defines the maximum number of estimated run times sent from Control-M/EM Server to the client for one cyclic job. Default: 50 |
NumberOfPastRunTimes |
Defines the maximum number of past run times sent from Control-M/EM Server to the client for one cyclic job. Default: 50 |
NumberOfFailedLogins |
The number of sequential failed logins after which an account is locked. Valid values: 0-100 Default: 0 (indicates that “automatic account locking” is not enabled and accounts are never automatically locked). |
NumberOfPasswordReplacements |
The number of password changes that must occur before a password can be reused (if PasswordHistoryOnOff is set to 1). Note: If a Control-M administrator uses the Authorization facility to set a password, this parameter is ignored. Valid values: 1-20 Default: 10 |
NumberOfReportDays |
Determines the number of days to keep report data in the database for generating reports about services. Valid values: 2 and higher Default: 90 |
NumberOfReportDaysHistory |
Determines the number of days to keep history report data in the database for generating history of services. Valid values: 2 and higher Default: 90 |
OutputAutoLoadLimit |
Determines the size of output data that Control-M loads automatically. If the output data size exceeds the threshold, then the user is prompted to save the output data in a separate temporary file. Default: 10000000 |
PasswordComplexityOnOff |
Indicates if passwords need to comply with complexity rules. Note: If a Control-M administrator uses the Authorization facility to set a password, this parameter is ignored. Valid values:
Default: 0 |
PasswordComplexityRules |
One, some, or all of the following values separated by a blank space. Multiple values are joined by AND logic. Note: If a Control-M administrator uses the Authorization facility to set a password, this parameter is ignored. Valid values:
|
PasswordEncode |
Indicates how user passwords are transmitted by clients to the server. Valid values:
Default: 2 |
PasswordExpirationOnOff |
Determines whether password expiration parameters should be checked. Valid values:
Note: When set to 0, other password expiration parameters can be edited but are ignored.
Default: 0 |
PasswordHistoryOnOff |
Determines whether password history is recorded. Note: If a Control-M administrator uses the Authorization facility to set a password, this parameter is ignored. Valid values:
Default: 0 |
PasswordLifetimeDays |
Determines the number of days before the password expires. Used in the password expiration date computation by the set_pwd_def_lifetime script. Valid values: 1 - 365 Default: 60 |
PermitManualUnlock |
This parameter specifies whether non-administrators can manually unlock their own tables (for example, if tables are locked during an abnormal disconnect from the GUI Server). NOTE: Non-administrators will not be able to unlock other users’ tables. Valid values:
Default: 1 |
PrivacyNoticeURL |
Defines the URL that links to the Privacy Notice from all Control-M clients, which outlines the privacy policy and compliance guidelines. |
ProxyNewsfeedHostPort |
Determines the host and port of the proxy server for all users connecting to the Newsfeed through a proxy server. Valid values: <host>:<port> EXAMPLE: Venus:13888 Default: Empty |
RecentItemsRetainDays |
Defines the maximum number of days recent items are retained in the database. Default: 60 |
RemoteBrowseEntriesMaxLimit |
Determines the maximum number of objects (files-directories) that are allowed for a Remote Browsing request. Valid values: Any whole integer Default: 1000 |
restricted_cm_admin |
Determines how to manage privileges for users and groups to access and update application plug-in connection profiles. Valid values:
Default: 0 For more information see Authorizing non-administrators to manage application plug-in connection profiles. |
RFAllowReportForJobLevelAuth |
Determines whether to allow users with job level authorizations to generate reports from Control-M Reports. Valid values:
Default: Y |
RFPGUseDeclareFetch |
Determines whether to enable the UseDeclareFetch option in Control-M Reports with PostgreSQL database. Valid values:
Default: 1 |
RunTimeDeleteHistChunkSize |
Indicates the maximum number of rows in the database of historical data to be deleted, each time a deletion is performed. Valid values:Positive integer values Default: 25000 Note: This system parameter is relevant only if Control-M/Forecast is installed. |
RunTimeDeleteHistInterval |
Interval in seconds between the deletion of historical records. Valid values:Positive integer values Default: 21600 NOTE: This system parameter is relevant only if Control-M/Forecast is installed. |
SecondsBetweenConnAttempts |
Defines the time interval in seconds between connection attempts. Default: 5 |
SendAlarmToScript |
Full path name of the script that is activated when an alert is generated. This script is activated only if the value of SendSnmp is either 1 or 2. Valid values:Full path name of the script that is activated when an alert is generated. Default: script_name When Alert data is sent as input to a script, the parameters are sent in the following format: call_type: "<call_type>" alert_id: "<alert_id> " data_center: "<data_center> " memname: "<memname> " order_id: "<order_id>" severity: "<severity>" status: "<status> " send_time: "<send_time>" last_user: "<last_user> " last_time: "<last_time> " message: "<message>" run_as: "<run_as>" sub_application: "<sub_application> " application: "<application> " job_name: "<job_name> " host_id: "<host_id> " alert_type: "<alert_type>" closed_from_em: "<closed_from_em> " ticket_number: "<ticket_number> " run_counter: "<run_counter> " notes: “<notes>” NOTE: The last data field is visible only if the SendAlertNotesSnmp parameter is set to 1, and in Control-M/EM 7.0.00 fix pack 2 and later. EXAMPLE: for testing SNMP traps when enabling this parameter On UNIX: #!/bin/sh echo $* > /tmp/snmptest.out On Windows: echo %* > c:\snmptest.out NOTE: On Windows, double back-slashes should be used as a delimiter. |
SendAlertNotesSnmp |
Specifies whether Alerts NOTES data field text should be sent to SNMP and script. Valid values:
Default: 0 NOTE: The SendAlertNotesSnmp parameter is available for Control-M/EM 7.0.00 fix pack 2 and later. |
SendPre800NamesAlarmScript |
Enables you to set alert field names and to send alarm exit scripts written before Version 8.0.00. Valid values:
Default: 0 |
SendRuntimeEstimations |
Specifies whether BIM runtime information updates are sent to the GUI. Valid values:
Default: 0 |
SendSnmp |
Indicates where Alert data is to be sent. Valid values:
Default: 0 NOTE: Alert data is sent to SNMP (values 0 or 2) only if the value of the SnmpSendActive parameter is set to 1. |
ShowNewsfeedDomain |
Determines whether the Newsfeed domain appears in the Control-M client. Valid values:
Default: 1 |
SnmpHost |
Host name or list of host names (if a list, using semi-colons (;) as delimiters) to send the SNMP trap on an alert. Specific ports can be set using a colon (:) as a delimiter. Valid values:Valid hostname or ip address Default: <no_host> Example: dhost1;jhost2;myhost3:2000 |
SnmpSendActive |
Determines whether SNMP messages for Active Alerts are generated. Valid values. Valid values:
Default: 0 |
SubApplicationFieldIsMandatory |
Enables you to set a mandatory Sub Application field for job definition. Valid Values:
Default: 0 |
UnsupportedClientVersions |
For BMC Software Customer Support use only. Valid values: List of releases separated by semicolons. For example, 7.0.00.100;7.0.00.200 Default: 0 |
UserAuditOn |
Indicates if the user will be required to enter details about the type of operation being performed and the reason for its performance, which will be saved as an annotation to the audit report, before completing the operation. UserAuditOn must be defined as 1 for UserAuditAnnotationOn to activate. Valid values:
Default: 0 Refresh Type: Manual |
UseAutoReconnect |
Defines the reconnection invocation method. Valid values:
Default: 1 |
UsezOSTimeZone |
Enables the to user to override the GMT value and ignore the value sent by Control-M/Server. Relevant to Control-M/Server for z/OS. Valid values:
Default: 0 |
ViewSysoutHeadSizeKB |
Displays the first KB of the output file. Valid values:
Default: 0 |
ViewSysoutTailSizeKB |
Displays the last KB of the output file. Valid values:
Default: 0 |
VMAdditionalJobsRelateFields |
Additional job related key fields to be defined by a user. BMC Software recommends that you not use the same job name (or mem name, in Control-M for z/OS) for multiple jobs. If you use the same name for multiple jobs, use this field to identify additional key fields that Control-M/EM can use to distinguish between different jobs with the same name/mem name, so as not to confuse or switch their job histories. A space must be used as a delimiter between key field values: HOST_ID OWNER CMD_LINE Recommended Values: DESCRIPTION, MEM_LIB, HOST_ID, OWNER, DAYS_CAL, WEEKS_CAL, CONF_CAL, CMD_LINE, FROM_TIME, TO_TIME, ACTIVE_FROM, ACTIVE_TILL Valid values: Do not change this parameter unless instructed to do so by BMC Software Customer Support. Default: <empty> Refresh Type: Manual |
VMVersionsNumberToKeep |
The number of versions of the job to keep, including the current version. NOTE: A job version is deleted only when all of the following are true:
BMC Software recommends not setting a value greater than 30 because of possible performance degradation. To deactivate version history, set the parameter to 1 (keep current version only). Valid values: Any whole number that is equal to or greater than 0. Default: 2 (current version, and one history version) Refresh Type: Manual |
WarningPasswordExpirationDays |
Number of days prior to password expiration during which a warning message is generated when certain utilities or scripts are run or a successful logon occurs. Valid values: 0-90 Default: 0 (no warning is generated) |
WarningSSLExpirationDays |
Number of days prior to certificate expiration during which the GUI server generates a warning message in the CCM. Valid values: 1-365 Default: 60 |
WebServersLoadBalanceEnabled |
Enables Web Server load balance by allowing emThrift web app to retrieve servers. Valid values:
Default: 0 |
WorkloadHistoryMaximumNum |
Defines the Maximum number of workload versions in the database. Default: 100 |
WorkspaceSharing |
Enables users to view a Workspace owned by other users. Valid values:
Default: 1 |
XAlertsEnableSending |
Determines whether the option to send exception alerts is enabled or disabled. Valid values:
Default: 1 |
XCTMDoForceAudit |
Enables a XCTM Do Force Audit Valid values:
Default: No |
XCTMDoForceRetryIntSeconds |
Defines the number of seconds that Control-M/EM waits in case of temporary failure, before trying to perform the force request. Default: 300 |
XCTMDoForceRetryTimeoutMinuts |
Defines the number of minutes in which Control-M/EM tries to perform a force request. Default: 1440 |
XCTMDoForceAuth |
Determines which component checks the authorization for running the folder/jobs. The component must have the authorization to perform the run according to the user that is defined in XCTMDoForceUser. Default value: EM. Note: If the value is set to CTM, Control-M/EM does not authenticate the request and it is authenticated by the Control-M/Server. |
XCTMDoForceUser |
Defines the user with authorization to run the requested folder/jobs. Default: use_job_owner |
Parent Topic |