Manual failover
You can perform a manual failover at any time from the CCM if the manual failover option is enabled.
The following scenarios describe the required conditions for a manual failover to occur.
Oracle/MSSQL/External PosgreSQL: A manual failover can occur in one of the following scenarios:
- If the the primary Configuration Agent is running:
- The secondary Configuration Agent responds to life check requests from the primary Configuration Agent.
- The database server is available for the Primary Configuration Agent.
- If the primary Configuration Agent is not running:
- The primary Control-M/Server is not running.
- The database server is available for the Secondary Configuration Agent.
Dedicated BMC PostgreSQL: A manual failover can occur in one of the following scenarios:
- If the the primary Configuration Agent is running:
- The secondary Configuration Agent responds to life check requests from the primary Configuration Agent.
- The primary and secondary Configuration Agent has access to the shared directory.
- If the primary Configuration Agent is not running:
- The primary database server is not running.
- The secondary Configuration Agent has access to the shared directory.
- The secondary database server is available for the Secondary Configuration Agent.